All Microlife blood pressure monitors have passed BIHS & ESH validation protocols.
BLOOD PRESSURE VALIDATIONS
The Microlife 3AC1: an accurate blood pressure measurement device in pregnancy and pre-eclampsia
The Microlife 3AC1: an accurate blood pressure measurement device in pregnancy and pre-eclampsia A. de Greeff, F. Reggiori, J. Anthony, A. Shennan, 2006 Introduction As
Accuracy validation of the Microlife 3AS1-2 blood pressure
Accuracy validation of the Microlife 3AS1-2 blood pressure device in a pregnant population with low blood pressure Hannah L. Nathan, Annemarie de Greeff, Natasha L. Hezelgrave, Lucy C. Chappell and Andrew H. Shennan
Rapid Assessment of Blood Pressure in the Obstetric Day Unit Using Microlife MAM Technology
Rapid Assessment of Blood Pressure in the Obstetric Day Unit Using Microlife MAM Technology Anja Wilton, Annemarie De Greef, and Andrew Shennan, 2006 Abstract Rapid Assessment
Validation and Compliance of a Home Monitoring Device in Pregnancy: Microlife WatchBP Home
Validation and Compliance of a Home Monitoring Device in Pregnancy: Microlife WatchBP Home Chung Y., de Greeff A., Shennan A., 2009; 28: 348-59. Objective To
Accurate semiautomated oscillometric blood pressure device
An accurate semiautomated oscillometric blood pressure device for use in pregnancy (including pre-eclampsia) in a low-income and middle-income country population: the Microlife 3AS1-2, Nathan, 2014. Hannah L. Nathan, Annemarie de Greeff, Natasha L.
Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy
Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy Thompson, Aliza M.; Eguchi, Kazuo; Reznik, Michael E.; Shah, Samir S.;
Accuracy of the BP A100 blood pressure measuring device coupled with a single cuff with standard-size bladder over a wide range of arm circumferences
Accuracy of the BP A100 blood pressure measuring device coupled with a single cuff with standard-size bladder over a wide range of arm circumferences Elisa Bonso, Francesca Dorigatti and Paolo Palatini, 2009
Accuracy of the Microlife large–extra large-sized cuff (32–52 cm) coupled to an automatic oscillometric device
Accuracy of the Microlife large–extra large-sized cuff (32–52 cm) coupled to an automatic oscillometric device Serena Masiero, Francesca Saladini, Elisabetta Benetti and Paolo Palatini, 2011 Validation
Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences
Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences Elisa Bonso, Francesca Saladini, Ada Zanier, Elisabetta Benetti, Francesca Dorigatti and
WatchBP Home A for opportunistically detecting atrial fibrillation during diagnosis and monitoring of hypertension
WatchBP Home A for opportunistically detecting atrial fibrillation during diagnosis and monitoring of hypertension
Detection of atrial fibrillation using a modified Microlife blood pressure monitor
Detection of atrial fibrillation using a modified Microlife blood pressure monitor 2009, Joseph Wiesel1, Lorenzo Fitzig1, Yehuda Herschman2 and Frank C. Messineo1 Abstract BACKGROUND: Hypertension is
Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation
Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation Joseph Wiesel, MDa*, Benjamin Arbesfeld, MDb, and David Schechter, MDc, 2014
Triage tests for identifying atrial fibrillation in primary care: a diagnostic accuracy study comparing single-lead ECG and modified BP monitors
Triage tests for identifying atrial fibrillation in primary care: a diagnostic accuracy study comparing single-lead ECG and modified BP monitors 2014, Karen Kearley, Mary Selwood, Ann Van den Bruel, Matthew Thompson, David Mant, FD Richard
Screening for atrial fibrillation with automated blood pressure measurement
Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations Willem J. Verberk, Stefano Omboni, Anastasios Kollias, George S. Stergiou, 2016 Abstract
Validation of the Microlife BP A3 PC upper arm blood pressure monitor in patients with diabetes mellitus according to the ANSI/AAMI/ISO 81060-2:2013 protocol, Beime, 2017
Validation of the Microlife BP A3 PC upper arm blood pressure monitor in patients with diabetes mellitus according to the ANSI/AAMI/ISO 81060-2:2013 protocol Beate Beimea, Ralf Krügera, Gertrud Hammelb, Peter Bramlagea and Cornelia Deutscha
Validation of the professional device for blood pressure measurement Microlife WatchBP Office in adults and children
Validation of the professional device for blood pressure measurement Microlife WatchBP Office in adults and children Anastasios Kollias, Angeliki Ntineri, Konstantinos G. Kyriakoulis, Emelina Stambolliu, Styliani Lagou, Nadia Boubouchairopoulou and George S. Stergiou, 2017
MEDGEM AND BODYGEM PUBLICATIONS
Variability of measured resting metabolic rate
Variability of measured resting metabolic rate - Haugen, H., Melanson, E., Tran, Z., Kearney, J., & Hill., J. Am J Clin Nutri. 2003; 78(6): 1141-1145. FULL ARTICLE
Validity of predictive equations for resting energy expenditure in US and Dutch overweight and obese class I and II adults aged 18“65 y
Validity of predictive equations for resting energy expenditure in US and Dutch overweight and obese class I and II adults aged 18“65 y - Weijs, P. Am J Clin Nutri, 2008; 88(4): 959-970 FULL ARTICLE
Hand-held indirect calorimeter offers advantages compared with predictive equations, in a group of overweight women, to determine resting energy expenditure and estimated total energy expenditures during research screening.
Hand-held indirect calorimeter offers advantages compared with predictive equations, in a group of overweight women, to determine resting energy expenditure and estimated total energy expenditures during research screening. - Spears, K, Hyunsook, K, Behall, K. et
Resting energy expenditure in overweight and obese adults: Agreement between indirect calorimetry and predictive formulas
Resting energy expenditure in overweight and obese adults: Agreement between indirect calorimetry and predictive formulas - Zielgler, J., Rothpletz-Puglia, P., Rouger-Decker, R., et al. Top Clin Nutr, 2010; 25(2); 180-187 FULL ARTICLE
A new handheld device for measuring resting metabolic rate and oxygen consumption
A new handheld device for measuring resting metabolic rate and oxygen consumption - Nieman D, Trone A, & Austin M. J Am Diet Assoc, 2003; 103(5): 588-592 FULL ARTICLE
Validation of the BodyGem hand-held calorimeter
Validation of the BodyGem hand-held calorimeter - Melanson E, Coelho L, Tran Z. et al. Int J Obes Relat Metab Disord, 2004; 28(11): 1479-1484 FULL ARTICLE
INDUSTRY-VALIDATED DIGITAL
HEALTH MONITORING
Microlife helps continuously monitor and manage acute and chronic health conditions with clinically-validated health monitoring solutions.